What is the differance between negative dc voltage and
positive dc voltage because some circuit uses -24,-5,-12,-
15,volt dc supply
Answer Posted / shakeel
i think when we supply positve potential then we found
positive output voltage and vicewarsa
| Is This Answer Correct ? | 0 Yes | 4 No |
Post New Answer View All Answers
in dc shunt motor if field winding is shorted then
why should small green grass ans small plant should not be there inside the transformer Yard in the factories
Which cable is use for rtcc control panel
How we calculate the current carrying capacity of H.T. cabel?
why we take movement of rotor always in counter-clockwise direction in 3-phase induction motors?
volts=230 c=10mf a=??
1.what is meaning of curve into a mcb. 2.what is basic reason changing of curve
testing of Vector Group – YNaoD II
Why mostly the HV side of transformer has Delta?
What is the settings of distance protection relay in 400 kv line
Define gain margin?
How to findout raw or ups power? its not indicated in socket,
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
when generator short circuit condition, the current how dissipates. or at short circuit voltage not available then current how can flow?
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.