Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why need 3 element system in power plant?
if it is not there then what l happen?

Answer Posted / kul bhushan emecon controls

In Power Plant three element control is always required
because when Load changes then steam flow will change vice
versa drum level & flow of feed water will change to manage
the action between all three perameters we require three
element control.Otherwise due to any mismanage between all
three plant will trip.

Is This Answer Correct ?    0 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.can you use SCADA instead of DCS,DCS instead SCADA 2.Difference between DCS and PLC,can their role be reversed i.e. role interchange 3.Difference between RTU and PLC

2598


What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?

3936


why I need valve guard and whats different between guard and positioner ??

1395


What is zener diode? What is voltage regulator?

1103


What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?

1925


What is the difference between working pressure and calibration pressure of a control valve

3070


How to fix back the valve actuator stem

2059


field bus transmitter calibration procedure tell me

1830


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1467


can you provide me full detail about instrumentation in ONGC??

2166


how many type of plug are used in pneumatic control valve,name them.

5445


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1902


Explain operation of Haskel pump.

2162


What is the procedure of calibration of Load cell?

1924


what is performance test.need defination

1714