what is the use of choke on tube light fitting
Answer Posted / suryakrishna.m
choke is used to give high starting voltage.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
how to calculate units consumption for a 12 hp motor /hr.
In a flange coupling, the flange bolts are designed for
What are the applications of autotransformers?
what will be happen if earth point is being used for as a neutral point for raw power , and same will be used for ups earthing
Explain what is use of lockout relay in ht voltage?
why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?
how solar power plant energy meter multiplication factor
does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain
why lightning arrestor are made in two stack of insulator but why not cvt
Single line diagram for dbb (double bus bar)system.
How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?
Types of test in Switchgears, MCC, NGR and DB's how it should be procced. Can anyone give me the details here or email me to pasuvaraj.k@gmail.com
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.