why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11
Answer Posted / a.mohanasundaram
i) Generating voltage strength (11KV) depends on dielectric strength of insulating materials to withstand heat loss produced by the main HV winding (armature). India has developed insulating material to generate maximum of 11KV (rms)
i.e) magV directly proptional to insulating material thickness
ii) Transmission votage is multiples of 11 bcaz
form factor = Vrms / Vavg=1.11 (sine wave)
to make average voltage 10 KV , rms sent as 11KV or 10% drop in voltage considered
Is This Answer Correct ? | 16 Yes | 6 No |
Post New Answer View All Answers
Difference between On Line capacitor and Station Type capacitor.
How you calculating the 30 Hp 3 phase AC motor of power what size of cable is used for this motor?
Is there any abbrevation for STUB in Stub bus protection
what is conductor copnstant of ab cable
what is a vector protection in transformer
what is the power factor used by the PHCN in nigeria? 2. what is the difference between an alternator and generator. 3. Generation of poweris in KV but how is transmission is in MW. 4.If the transmission of power is 20,000MW how can it be increaesed to 80,000MW
How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?
12.5 tons a/c is their how much kva generator can recommend to the customer.
Benifits of 3ph 4 wire metering over 3ph 3 wire
describe the fully control circuit diagram of ac drives
A 11KV, 1200 A breaker combination fixed in a cubicle for HT motor.Is normally for 11 KV motor fuse is using? if Yes, What range fuse is required?
Draw the vector diagram and condition for the following: 1) Dyn1 2) Ynd0 3) YnYn0
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?
Actually I have a doubt on neutral and earth.we use Ac power without taking neutral by connecting to earth,but at that time does it affects on efficiency of any electrical components or no? If yes how?