why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11
Answer Posted / a.mohanasundaram
i) Generating voltage strength (11KV) depends on dielectric strength of insulating materials to withstand heat loss produced by the main HV winding (armature). India has developed insulating material to generate maximum of 11KV (rms)
i.e) magV directly proptional to insulating material thickness
ii) Transmission votage is multiples of 11 bcaz
form factor = Vrms / Vavg=1.11 (sine wave)
to make average voltage 10 KV , rms sent as 11KV or 10% drop in voltage considered
| Is This Answer Correct ? | 16 Yes | 6 No |
Post New Answer View All Answers
Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.
what is the difference between the voltage of 5 volts capacitor and and 5volts battery?
What are the specifications for conducting earth leakage test as per IEC standard?
Why i receive the GCU fault in my DG Sychronization panel . what all the factors considered for this fault .
What is expention fastener (Fan)
how to find the multiplication factor for digital energy meter and analog energy meter
can anybody send the rrb chennai &rrb bopal question papers of 2006&2007.My exam is on 12 oct 2008.Its urgent
HOE WE CAN IMPROOVE BY USE OF CAPACITOR
Give idea about General Engineering. From which book i can study this topic. Pl. reply me via email. My email is ravi@bhelhwr.co.in, also give the name of book/website, from where i can prepare it.
At what speed 1 HP motor can run an electric car of weighing 400 kg?
State norton’s theorem?
please send me previose rrb junior engineer qustion papers
i am completed diploma in ece,and working in ht and lt lines.so is elligible diploma in ece for get electrical C Licence?plse give ur opinion?
What is meant by derating factor?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?