what is coriolis principle for mass flowmeter?

Answer Posted / omak

If there is no flow then no coriolis effect, if there is a flow then it will make coriolis effect. In coriolis flow meter, consists of two parellel flow tubes connected with a drive coil and two magnetic pick ups on either side of the tubes. During no flow condition, the drive coil makes a small vibratio in the tubes one another. Due to this vibration the magnetic pickoff coil will generate a voltage equilant to a sine wave. In this condition sine wave created by both the inlet and outlet magnetic pick up is same.
During in flow condition, then there is a twisting in the flow tube. In the inlet side the flow opposes the vibration and in the outlet side the flow adds the vibration and makes twistinh in the flow tube. Due to this twisting the pickoff coil makes different sine wave output. By measuring the phase shift with reference time will be calculated as t in micro seconds. Multiply t with the calibration factor, we will get the mass flow in grams/sec.

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is cold loop? difference between hot and cold loop?

1838


Q- What are the application in which PNP transistor is preferred over NPN ?

2942


what are the use of belew gear in general ??

1640


key exchanges in wpa,wpa2,tls

1600


what is piezoelectric transducer?give an example in power plant n state its principle?

2194






What is intrinsic safety mean.

1552


What is the main difference between Cavitation and Flashing?

13585


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

3552


What is ultrasonic flowmeter?

734


Differentiate between ultrasonic flowmeter and radar type flow meter

859


Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?

2017


my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card

1899


what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?

1838


what is use of communication wire in multipare cable(oil and gas field), why this communication wire not used in single pair cable?

1764


How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.

1183