Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Difference Between Isolator and Mcb

Answer Posted / nikhil hari

Isolater is used to isolate our devices form Supply. but
there is no protection in isolater. If any fault current
comes our devises or isolater get damaged. Eg: Switch
But MCB is used for circuit protection rather than
isolation.If any fault current comes MCB will trip and
protect or devise.
Different types of MCB's are there B,C,D curve MCB. that
depend up on Instantinous tripping Chara of MCB.

Is This Answer Correct ?    26 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2514


What is the end effect of linear induction motor ??

1955


When we need up only in o/p 440v, so why we use directly in 11kva in input?

1633


The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is

1073


give me a clear defination of inductance,and how can u calculate inductance of a motor

2739


Whar is the KvA rating of 33Kv substation & actual kv rating of power generaating station.

2332


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2656


On 400 amp factory load how kvarh capacitors provide

1653


If I want to buy a new Xformer for my plant what are the main parameter will I need to check?

1850


1.dg on load alarm/stop alarm... 2.dg on load. piu alarm alarm kaise chek krte hai

1886


What are the limitations of Kirchoff's laws?

1525


Ceiling Fan and Storage type water heater. Discuss

1903


Explain how to determine capacitor tolerance codes?

1115


Define conversion efficiency of a power amplifier. What is its value for class c power amplifier?

1278


What is the principle of HIGH SPEED DIRECT DRIVE MOTOR ?

1946