Answer Posted / ashvin timbadiya
CNC (Computer Numerical Control) is a particular application
usually to control a multi axis machine tool such as a
milling machine or a lathe but also could be a tube bending
machine punch press or similar. The CNC controller is
usually a purpose built controller using a micro computer
but could be a general purpose computer or a PLC. The
forerunner was NC (Numerical Control) before computers were
readily available, it used solid state logic and relays,
timers etc to provide the application.
A PLC (Programable Logic Controller) is a general purpose
logic controller specifically designed to allow the user to
create their own application. They select appropriate I/O
(Inputs Outputs) and perhaps function modules for purposes
such as communications and multi axis servo control and
program the PLC to perform the required functions.
| Is This Answer Correct ? | 8 Yes | 0 No |
Post New Answer View All Answers
Explain bernoulli’s theorem. State its application.
why we are using drum level control valve air to close?
when a magnet is heated?
Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
how will you segregate the alarm levels in alarm management system during factory Acceptance Test
a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
How ejector(or)evactor air pump is working in thermal power plant?
what is the vital subject for scoring bhel exam&what is the question pattern
Somebody can explain me about >Critical Loops, calibrations, ESD critical Loop checks, Logic Diagram / Cause & Effect checks for ESD loops,
In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.
How can you add value to this Industry if offered the job?
how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744
why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is further divide by 32 in UART serial communication ??