Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in determination of(acetone) moister content we are using
methanol replaced by pyredine.what hapend in that reaction.

Answer Posted / t.tirupathi rao

acetone is react with methanal to form water molecule continue, end point not reached.so pyridine is added to methanol, pyridine is bind the hydrogen molecule in methanol,so do not form the water molecule ,end point reached

Is This Answer Correct ?    9 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much is the standard area for glc analysis

2287


why require to add enzymes in capsules dissolution only? is it require to tablet also?

679


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3669


Colorimtry

1660


if content uniformity passing but dissolution varrying then what is next step?

878


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1597


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2887


Which products will produce when acetic anhydride reacts with Ter-butanol, Sec-butanol, Iso butanol, Dimethylamine etc.

2865


What is the difference between spectro meter and spectro photo meter?

11515


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3178


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

1973


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

2964


why lactose has less charges when packed in steel containers when compared with packing of lactose in polyamide material?

2299


Did anybody have method for acetyl cysteine effervescnce tablet

2254


give clarity of linearity and range in method validation