Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between earth fault and restricted
earth fault protection?

Answer Posted / m.gopinath

Earth fault protection is non-unit protection for earth
faults where as restricted earth fault protection is a unit
protection (ie differential protection of Y connected
alternator/transformer) for earth faults. So we can say the
Restricted earth fault protection is differential
protection of a y connected winding for earth faults only
but not for phase-to-phase faults.

Is This Answer Correct ?    7 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In India the supply voltage is 230 volt A.C. During the negative half cycle phase becomes neutral and neutral become phase? or what will happen during negative half cycle? how the electrons flow during positive and negative half cycle?

2022


I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)

2137


what is negative and zero impedance in 3 phase induction motor ??

2187


what is load vs Torque curve & why it is used?

2082


what is the difference b/w ATS and HTS?

2198


Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,

1654


Electrical 'C' license full abbreviation , and full form

1904


What is the formula formula for Busbar sizing and what are the things to be consider for Busbar Calculation?

2561


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1935


how many joint can done in HT line and what is life of the joint

2241


Why i receive the GCU fault in my DG Sychronization panel . what all the factors considered for this fault .

2237


Any Electrical Engineering jobs?Please refer for interviews. Thank you

1925


What is the armature mmf in a D.C machine?

1247


A TRANSFORMER 440/400V,DELTA/STAR CONNECTED.THE NEUTRAL CONNECTED WITH GROUND CABLE THAT IS DIRECTLY CONNECTED TO THE PANEL,FROM PANEL IT IS CONNECTED EARTH PIT.IS IT RIGHT? IF IT IS RIGHT LEAKAGE CURRENT AFFECTED.SECONDATY IS PROTECTED WITH EARTH LEAKAGE RELAY.

2116


Single line diagram for dbb (double bus bar)system.