I am working in 600MW power plant currently in erection
phase. I came along this term and want to know its meaning
in simple language, consider me naive!??
All motors shall be of energy efficient type EFF-2 as per
IS:12615/ equivalent IEC /
International Standard.
Answer Posted / k.prakashchandra
the answer is in the question itself. Those motors are
energy efficient i.e.maximum efficiency and least losses
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
What is meant by reactance voltage?
How one may guess the direction from which the distribution line is incoming if there is no pole plate on poles?
How one can check the MAIN of a house wiring ?
What is stepper motor. What is its uses?
Why the field rheostat is adjusted such that the voltmeter reads 380V
When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?
what is a pilot wiring and whys that called a pilot wiers
while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends
Explain cos(theta) and Sin(theta)
How many types of electric motors are there?
In a synchronous motor. if start is running at high speed. What will be the starting torque : Higher Lower Zero
Can we use shunt trip coil instead of trip coil with protection relay for protection?
In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.