Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what do you mean by PF correction. A motor is rated at 15
kw,415 volts, 0.7 pf and eff of 0.92. The powerfactor is
improved to 0.98 by adding capacitors at the bus. calculate
the current drawn by motor under full load condition before
and after pf correction

Answer Posted / technicalarticlessbsvbsbsvb

No change. whatever was at rated pf will continue to be
drawn

Is This Answer Correct ?    2 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why corona leads to production of Ozone and glow of the color VOILET?

2038


In India the supply voltage is 230 volt A.C. During the negative half cycle phase becomes neutral and neutral become phase? or what will happen during negative half cycle? how the electrons flow during positive and negative half cycle?

2082


what is the working principle of a DG Set, Alternator, & exiter

10265


how calculated Transformer losses.

2089


Don't you have similar question banks related to Oral Certification Examination conducted by Mercantile Marine Departments / Directorate of Shipping, Ministry of Shipping for Electro Technical Officer?

1720


What is the difference between Generator Differential Relay and Transformer Differential Relay?

2322


Transmission voltage is kept 11KV,33KV,66KV,132KV,220KV due to form factor. What happen to 400KV and 765KV transmission voltage?

2232


i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.

1984


List out the different frequency domain specifications?

1285


Power Factor Correction Panel (Manual & Automatic)

2286


What are Contactors? How they works and what its highest rating?

2212


Define characteristics impedance?

1180


HOW WORK HEAT PLATE EXCHANGER

2047


ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH

4201


How does a battary stores charge in it? please explain in simple manner and in detail.thanks

2035