Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to check electrical health of vibration probe?

Answer Posted / aftab ahmed mazari

First you know which type of vibration probe you using.
Suppose you using proximity probe. Then check followings:
1. Its resistance, usually Bently Nevada common probes
restance varies from 4.5 ohm to 6 ohms. But if you using
asnother company probe, then see its literature.
2. Also make a graph of vlotage vesus distance of probe,
its behaviour should be linear.
3. If you have vibulator(Vibration source), then check it
with diffewrent vibrations.
aftabmazari@yahoo.com

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hello can yoy pls send me previous papers of jindalpower and steel ltd.....'m from instrumentation..... mani1048@gmail.com

1984


how to calibrate 0- 150 psi presure gauge by dead weght tester

2003


How to Calibrate Ultrasonic flow Transmitter in Field

1255


State bernoulli’s application.

1136


Give Detail information about plc,dcs,and scada system?

1725


There are two chlorination tonners both are connected to two pressure swithes and the pressure switch is connected to SOV which operates the valve to changeover the tonner selection i.e if pressure one tonner goes low the other tonner should come in line if it is inautomatic selection design a circuit using relays ?

1955


How earthing can be checked????

2399


please tel me the calibration of pneumatic controler.

2143


send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com

2205


why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is further divide by 32 in UART serial communication ??

7544


what is your eligibility criteria for freashers?

2132


what would be the minimum flow rate that we can measure on rotameter..?

2085


How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)

2589


Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure

1987


what is thermo coupler and how it works

6063