what is the use of performing tapped density in
pharmaceutical industry
Answer Posted / jagadeeshchandra
Tapped density is used to know the flow ability of the
sample.The flow ability of the sample is importent factor
to determine in pharmaceuticalindustry by determining the
compressibility factor or houser ratio.Samples with better
flow will have ratio nearer to houser ratio 1.
flow ability is importent to determine because the tablet
formation will depend on it.Compresibility factor can also
be known with tapped density.
Bulk density or un tapped density or pour density is the
density of the sample which is un tapped.Where as tapped
density is density the sample occupies after tapping it
mechanically.
There are two methods to determine tapped density.
USP methdod I
USP method II
Tapping is done mechanically by raising the measuring
cylinder and allow it to fall freely under gravity.
density= sample taken/volume it occupies.
Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)
What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?
CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?
can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?
what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means
What should be the level/ Percentage of Arsenic in Arsenic free zinc.
How will u perform degradation study in detectors other thann PDA in HPLC Methodology
i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me
We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?
if rsd failed then what require to do?
if identification threshold crosses the limits then what next step?
How to set analytical specification for combination products?
which are the diffrent batches in the pharmaceuticals?
Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .
How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.