Answer Posted / jagadeeshchandra
TLC means Thin layer chromatography.
Chromatography is a seperation techinique.Chromatography
is used to seperate components present in a mixture in to
individual components.Seperation of components is very
importent in pharmaceutical industry to know the nature of
the sample.So,we use TLC.
Uses of TLC :
1.To know the no of components present in a mixture.
2.To choose approprate solvent for column chromatography.
3.To moniter c-c seperation.
4.For reaction monitoring.(during in process of batch)
Procedure&principle:
One or more components are spotted on a adsorbent coated
chromatographic plate and this sample spotted plate is
placed in a solvent ie mobile phase and this mobile phase
is adsorbed by the plate slowly from downwards to upwards
due to capillary action agnist gravitational force.The
components with lower affinity towards mobile phase travels
slowly,and the components with high affinity towards mobile
phase will move faster.Thus components are seperated on a
tlc plate.
TLC PLATE:
The plate is the stationary phase.solvent is mobile
phase.TLC plate is nothing but silica gel like kiesel gel
60F254,silica gel 60F254,cellulose powder is spread on an
alluminium foil,or glass or plastic plate.
We can say more about TLC but not possible to say hear.
Refer web pages,you will get more information
| Is This Answer Correct ? | 9 Yes | 1 No |
Post New Answer View All Answers
what is %labelled amount in content uniformity of dosage unit and its calculation?
what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?
In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?
what is definition of validation? which components are followed give detail?
how you start RS method development when for new product?
what is mean by extactable and leachable study?
What if impurity area in control sample coming more as compared to LOQ level of impurity ?
Identify problem faced when mass spectroscopy is used with HPLC system ?
how many types of balance calibration test?
If we have 5 strength which is not dose proportinate and excipients also diffrent in each strength then how we can proceed for Force degradation? and excipient are same but not dose propotinate the how FD?
What is the Formula for coreletion coefficient in plhplc calibration
if you have given a blank water how you analyse by general analytical techniques?
What is the formula to determine the concentration of M of a solution given the % transmittance? Use %T = 43.7 as an example.
What is the use of tlc and hplc? And when and where use?
Which parameters require to do in tech transfer?