Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

void volume is depending on column or not? if yes how will
you depend?

Answer Posted / balaji

Yes column dependant.

Why because:Total volume of mobile phase in a fully wet
packed column- the space between the particles of the
stationary phase plus the volume within the particles

So,based on length,internal diameter and particle size of
column it varies.

Is This Answer Correct ?    17 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is %labelled amount in content uniformity of dosage unit and its calculation?

5303


mode of absorption in alimentary canal?

2434


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1653


Is it nessesary all multimedia dissolution require descriminatory?

860


What is gelatinization?

1673


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

3025


in which situation ion pair agent require to use?

800


What is related substance by HPLC impurity limits as per USP?

1155


using gradient pressure in gas chromatography are not ?using gradient pressure why

3440


What is the formula for relative diffrence for standard solution in solution stability in validation?

863


How to set analytical specification for combination products?

875


in OSD forms require to use gas chromatography?

874


What is aggregate and fragments in SEC?

2158


WHAT IS THE USE OF STARTER ?????????

2472


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

2097