why nutral and earthing wire connect with each other in
main panel board.?
Answer Posted / sagar soni
if in any circuite there will be leakage current than it
would return back via neutral and it is harmful to the
circuit and if earthing is provided that leakage current
passes via earthing without any harmfull to the circuit and
equipment.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
How to calculate the sag on transmission Lines.
hi, i finished b.tech eee in 2008, im worked in dg sets mfg company , now i left job in 6months back, now again i want get job core side, how can i get? is there any couses we have learn to get better oppurtunity? /
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.
1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor
what is the criterion for selecting vector group of Transformers ? i mean how to decide vector group of Generator transformer, substation trasformer and transformer at consumer end
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
what is The difference between national electrical code and I.S.Code (electrical) and what is the value of NEC in electrical engineering field
Explain what is rated speed?
What Is HO factor in power selection
How to select a transformer group to connect a 0,433 KV generation with 33 KV grid in bi directional flow of current
On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?
CT Ratio of a energy meter connection is Red Phase : 100/5A, yello Phase : 50/5A & Blue phase : 100/5 A what is the overall Multiplication factor
Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?
why don't we use the generator as a motor? and what will happen?