Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How much should be the specific gravity of a DG set battery
Electrolyte.

Answer Posted / shariff

The SG should be 1200 when it is fully charged.. for over
charged it is > 1200, and less than 1200 for discharging.
The SG will vary with temp. (increases with temp.)

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

ult of expression 'document.FrmQF.myem

2078


can i use 4 number of circuit breaker as single phase manual change over switch? if yes then how plz also send ckt diagram at nazimzamurad@gmail.com

2129


For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?

1827


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1927


What is pole of the system?

1151


Why we use ups battery and dsdb battery in thermal power plant

2094


Define the overload capacity of the motor?

2050


what r the safety measures in UPS ? explain all?

2222


WITCH CARDS IN USE IN FIRE CONTROL PANEL.

1932


How we can defined theecopper cable size if we know the aluminium cable size?

1876


formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?

2206


If more than rated DC voltage appears across trip coil of the breaker, what will happen? e.g. in 110V DC circuit system, if voltage across battery terminal showing 121 V

1659


What are Contactors? How they works and what its highest rating?

2143


i need mat lab program to find out the transmission line losses,regulation and losses

1900


what is mean by dual digital protection in the relay field?

1938