Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to convert single phase supply to 3 phase or 3 phase to
single..?

Answer Posted / gopal manda

it can be possible by scott connection of two single phase
transformer.convert single phase AC to 3-phase AC supply

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2117


Terminal blocks is used for segregate the connections... There is any principle for terminal block..?

2126


how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?

1140


In layman terms, what is the difference of Dielectric strength and dielectric constant when speaking of an insulating oil

2708


is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?

1861


How to calculate impedance volt in Transformer?

2089


what is 3rd Harmonics? how it is generated in alternator

9486


What are dcs and plc?

1106


as a electrical student why should i hire you?

2499


what r the safety measures in UPS ? explain all?

2222


Explain thin film resistors and wire-wound resistors

1028


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1796


What is force on parallel conductors ?

1079


Why a tesa lamp is glow between two phase?

2009


why three phase capacitor takes unbalanced current in capacitor bank?

1495