how we test a 3 phase motor on single phase supply....?
HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for
testing..?
how we verify of a 3 phase motors 6 wire & name thame
a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta
starter ........i have only 1 phase supply ? help
forum..........
Answer Posted / k.prakashchandra
You can test-run motor with 1 phase supply treating it as a
capacitor start/ run 1 phase motor.There are 6 leads a1,a2&
b1,b2 &c1,c2 of each phase.Short a2 and b2 and connect it to
neutral. Give phase directly to a1 or b1 ,and give supply to
the other trough a suitable capacitor.Similarly, change the
phases
| Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
How do i carry out or know the vector group of a Dyn1 and Dyn5 transformer
Why temperature rise is conducted in bus bars and isolators?
What is the difference between Generator Differential Relay and Transformer Differential Relay?
why we are using Load factor?
If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines
If not into production, how far did you follow the design and why did not you see it into production?
How do we calculate the Out put voltage of generator, after the excitation is being given?
what heppend if we are connected u1-v1-w1 as a star point in the place of u2-v2-w2 in power genration
What Is HO factor in power selection
What is the function of NGR for the parallel operation of alternator? whats happen when different rating of alternator are running with parallel?
what is the difference between c power and U power acb breaker
How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts
Hi friends, i m electrical engineer i want a cdr for migration purpose so anybody have information about this then send me on jayesh_ee88@yahoo.com.please try to me
Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?
How to select circuit breakers rating eg. if i select a circuit breakers of capacity 40 amps DC with operating voltage 28 volts and if i what to use same circuit breakers for 300 Volts DC application what is the current rating of this circuit breakers.