Answer Posted / naresh
when ever there is a fault the current value increases........
the fault is a sub transient condition.....
the reactance offered during first few cycles of faulty
condition the reactance is very less(bcoz in alternator all
three winding's damper,field& armature are connected in
parallel )and the fault current is more..........
after few cycles the current level decreases(bcoz out of
these winding's damper winding cut's off due to lesser time
constant, now field& armature are connected in parallel) due
to increase in reactance this reactance is called transient
reactance.......
after few cycles the field winding cut's off due to lesser
time constant and only the armature winding is present, this
reactance is steady state reactance.........
steady state X > transient X > sub transient X
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps
how can we design robots
How much weight an electrical engine can pull??
what is the difference between "Rotary bypass isolation switch and Normal bypass switch" pls share indepth techs?
magnetizer priciple
What facility we get after CT secondary earthing and how?
the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?
It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.
Greeting to all members, How to calculate spill current when we have different ratio CT and Class for REF(Low Imp) I have 500/1A 5P20 @line side n 400/1A CL.X @ Neutral.
How is the speed of a DC shunt motor related to the armature current?
11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?
What are the types of class b amplifier?
how to calculate voltage drop and followed by cable calculation?is there avail in formula?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.