Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In any plant or substation main incommer voltage RY - 415
V,YB - 400 V, BR - 387 V(in commer feed from transformer 11
Kv /0.415 KV) why found voltage differance in each phase?
plant have not self power plant it is depend on outsource
grid

Answer Posted / k.prakashchandra

If this condition is on no-load, replace tr

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to find out 3 phase complex power in per unit in unbalanced system?

2038


what is the difference between ups & inverter

7159


what is destructive and non-destructive testing of welding

1686


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1590


wat is the first thing dat is needed, 2 lay a cable in some area??

1860


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2382


how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec.

2278


WHAT IS DEAD END IN PROTECTION?

2592


What is the function of interposing current transformer?

1057


what is the purpose of using filters in a protective relaying scheme?

2268


Why can't we parallel the secondary circuits of two voltage transformers?

1535


we have 3 single phase transformers. how will we generate 6 supply from 3 phase supply input

2120


How to calculate the Harmonics losses in terms of cost/unit.

2027


What is the comparison of PILC and XLPE cable

2146


sir i have a car stereo system and there is jack on him so can u tell me a way to find out their power terminals on the jack or on the circuit board"

2059