Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the function of end capped column?

Answer Posted / premraj behera

All the packing material(active silanol group) has been end-capped(fixed) with trimethylsilyl/double end-capped with dimethylsilyl and trimethylsilyl group. End-capped stationary phase increase column stability and reducing the solubility rate o f the silica support, and also useful for rugged method development. Double end-capped column appears to further increase column stability.

Is This Answer Correct ?    14 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the structure of DOWEX-50

5447


What is rs test why we are performing rs test?

1798


how you determine moist.of NaOH sol or NaOH flacks

2173


What is the principle of HPLC, GC, LCMS, GCMS,LC QQQ, GC QQQ, LC Q TOF and GC Q TOF. What are the applications and Specificity?

8804


in which situation require to take incident in validation?

1645


function of detecter in hplc ,gc and spectroscopy? function of carrier gas in gc?

2605


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2260


Why we use potassium dichromate in uv calibration Exact reason behind it??

1184


why octanol used to determine the partition coefficient ?

2393


Basic principle of ESI?

2093


before starting analytical method valodation what you checking? and how giving preference to start validation?

748


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3818


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1789


what is the purge flow & how to calculate

2557


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1835