Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between PLC & DCS

Answer Posted / bf chauhan

Basic difference is that PLC have 2 software for operation
one is SCADA Software and other is Programming software
while DCS has only one software which work as programming
as well as graphic building.

Also PLC mostly used where descrete IO are more and Analog
IOs are less while DCS are preferred where descrete IOs are
less and Analog IOs are more.ie. DCS is more suitable where
no. of closed loop are more.

Also DCS has have greater flexibility than the PLC.Analysis
of the process and report generation is better in DCS
compared to PLC.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

wich is coming the first HAZOP OR SIL

2759


Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

2280


Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose

2256


What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?

1399


How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System

1369


when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??

2185


How oil line flow measured?eplain about instruments used and working principle?

2059


how to calibrate 0- 150 psi presure gauge by dead weght tester

2017


Meaning of the following a. IOP- Manimum; b. IOP- Maximu,;

2183


Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .

1705


How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?

2460


Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?

1990


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10848


What is the difference between working pressure and calibration pressure of a control valve

3069


what is the importance of CV in the control valves? how it is calculated?