why spark is produced in mosquito bat?and what are the ways
to reduce it?
Answer Posted / ravi pradhan
The net structure is primarily made up of three layers of metal mesh and is rather a complicated assembly.
The inner central layer is actually the "hot" mesh and is terminated as a high voltage source from the circuit enclosed in the lower handle area. The outer two layers are simply connected with the negative of the battery and constitute the ground for a return path to the central “hot” mesh line.
However since the inner layer and the outer layers are separated from each other at a reasonable distance, the high voltage from the central mesh in unable to arc-off through the outer layers, but when a “victim” (a mosquito in this case) flies into this trap and bridges itself in between the layers, its body creates a low resistance path in between the layers of the mesh so that the high voltage is now able to arc through the body of the mosquito which is instantly electrocuted.
The circuit supplying the required high voltages to the above mesh in fact becomes the heart of the whole procedure
The boosted voltage ranging several thousand volts gets stored inside an output AC capacitor across the output HOT ends which are finally terminated to the bat meshes and becomes ready to “shoot.”
The moment a mosquito or any bug comes in contact with the meshes, the stored high voltage in the capacitor discharges violently through the body of the entangled bug creating a big spark and electrocuting it instantly.
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
why cable i burning without tripping. how can protect led street lights
how a flip flop can be used as a latch?
what is apparent poewr, reactive power, & active power?
I WANT HOW CALCULATE TO CABLE FOR WELDING PLANT ?
What is an alternator impedance value?
What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB
There is any especial requirement for motor to drive through with VFD?
what is RFCT and Insulgard Relay & It's function?
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
Load transfer in 11kv double busbar switchgear - operation.
why motor range is available 22kv,30kv,37kv,45kv and so on? why motor range is not available 21kv,24,25,26,27kv and so on?
Why do we mostly prefer to generate and distribute electricity in 3 phase and not in 4 phase or 5 phase?
We have Diesel generator of 200KW. fuel consumption is always same,even connected light load or full load. Is it right?
stand by earth fault protection (51G) for transformer rating 2000 kVA,Dyn11,33/0.400 V. LV NCT ratio and necessary resistor and metrosil values how to calculate
i karmveer bharti persuing b.tech . plz send me syllabus and name of reference books. for preparation of section eng.