In electrostatic precipitator why positive terminal of
tranformer rectifier unit is grounded?
Answer Posted / amit sharma
actually a dust particle is having -ve charge and it is
attracted by a +ve charge.
so for the collection of dust particles by the collecting
plates, they should have +ve charge and there is only a way
to get +ve charge.
| Is This Answer Correct ? | 8 Yes | 5 No |
Post New Answer View All Answers
All tape of electrical questions Answers tape of motor transformer e.o.t crane
How to calculate cable size by using load.?? Any formula...
why moisture formation found in XLPE Armoured cable outer sheath
What should be the values of settling time, peak time, steady state error, overshoot, rise time, MPOS (Maximum percent over shoot) to keep the system in transient state, to keep the system in steady state ?
How do we calculate over and under frequency tolerance from generator data?
what reactive how to maintain
Is there any abbrevation for STUB in Stub bus protection
Explain The Application Of Storage Batteries?
what is the principle of operation of CFL ??
how to select correct size of power cable for inverter duty motor
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
Explain Circuit Breaker Trip Characteristics in detail.
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
what is the criterion for selecting vector group of Transformers ? i mean how to decide vector group of Generator transformer, substation trasformer and transformer at consumer end