Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is use of starter motor in DG ?

Answer Posted / saleem pasha

the diesel generator is a combination of diesel engine couple to a generator( alternator), the engine is a prime mover which in turn rotate the rotor of generator as a result it induces EMF across stator first,the engine has to be started either manually or by electrically, if the engine is of high capacity then it has to started electrically with the help of electrical starter motor, initial crank or rotation to the engine is given by motor with a high starting torque so as to start the engine , when the engine picks up speed the starter motor is disconnected and pinion is detached from the fly wheel of engine and engine run on its own,and rotor of the generator which is couple start running as long as the engine is running and produces and supplying electrical power.

Is This Answer Correct ?    15 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the reason that the humming sound is coming from the induction furnace panel?

2542


for 11KV OH system what will be typical per KM "R" "L" "C" parameter. for 33KV OH system what will be typical per KM "R" "L" "C" parameter. for 33KV UG system what will be typical per KM "R" "L" "C" parameter.

2396


Why do we avoid electrical conduits in floors at apartments?

2018


What are the various types of BUSBAR Schemes? explain each

5228


Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?

1153


What is the Good Earth resistance value of G.I & Cu. Chemical Earthing & Normal Pipe Earthing?

2269


Define phase lag and phase lead?

1069


Star Delta Diagram with full description

2331


What is difference between safe PLC and normal PLC

1525


In single phase ac ups supply when current is measured with tong tester neutral current is found more than phase current.What is the reason?

2070


What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?

1901


which protection used in power plant?

1890


Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.

1803


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2415


Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?

2476