Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transmition and distribution and genaration of voltage
in multible of 11 means 220v,440v,11kv,22kv,,,...so on

Answer Posted / shariff

It is the standrad maintained by the utilities and there is
no technical reason for that... It can be transmitted or
distributed to any vg levels with use of the transformers
of that rating.. but due to huge investment and already the
system is standradised so the same were maintained.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Electromagnetic torque developed by the motor is compared to shaft torque. A less B same C depends on motor design D more

2024


What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load

1836


what are the installation procedure of high voltage power transformer,CT,CB&PT?

2051


how to setting voltage RTCC panel

1663


How can we find out LT UG cable fault (size,from-4*25mm sqr to 4*300mm sqr)? How mani types UG cable faults?

3051


we are having 110 Kv,250mA Electrostatic precipitators for coal fired boilers. what will be static voltage and current after discharge and what time it will remain before earthing?

1885


Define demand factor?

1101


one split ac how can told of this ac which Tr tell me us

2027


what is earth-fault?when it occurs? to check where it occurs what type of test should we do?

1994


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

2069


how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?

1723


from generating station If 400v LT line length is 1000m how much voltage is drop and how do i calculate it? which cable will be use for this line?

2022


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1942


what does vector group Dyn11 tell us? also tell me how will u differentiate between phase lead and phase lag thru this vector group

2073


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1776