Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1. what is the power factor of a purely inductive load?
2. Which type of transformer connection is preferred in
case of power supply transformers?
3. In power transformer usually which winding is closer to
the core?
4. what will happen to the generated emf if the no. of
poles of an alternator is increased?

Answer Posted / lakshmi

power factor is zero because angle between voltage and
current is 90 so cos(90)=0 so therfore reactive power is zero
2.power transformers are preffered
3.low tension winding is preffered because smal insultion is
required.
4.as poles increase speed decrease inturn generated emf also
decreases

Is This Answer Correct ?    0 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What's the difference between non break power supply and non break non short break power supply

1505


what is the chemical name and formula of refrigarent R-134a.

2338


how to find the capacitance value of the motor while running??

1969


A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why?

2032


What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.

2459


What is the voltage gain or transfer function of amplifier?

1178


What are the basic & Majour problems in UPS ?

2172


hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .

1540


What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation

1959


What can you contribute to the progress of our Company as an employee if you are selected?

5472


How eddy current generation support the idea of train braking?

2061


what is a bus riser in power system and why it is used

46352


A 3 phase transformer's (Y-Y) Y and B phase is (Y and B connection not broken) broken from neutral and R and Nutral connection is ok, what will be the relay tripping and why

2008


In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.

2170


What is the purpose of stand by earth fault protection for transformer ?

2130