What is the basic principle of vibration measurement by
BENTLY NEVADA vibration measurement system? and Why it
gives the -ve voltage output?
Answer Posted / m. saqib ali nafees
AN EDDY-current probe works on the basic magnetic principles
(Faraday's law and lenz's law) when an electrically
conductive material comes close to the probe we know that
alternating current pass though coil this alternating
current produce EMF in electrically conductive material
(observed surface) by Faraday's law. This produced EMF
oppose its source by lenz's law. ( when the current through
a coil changes and an induced voltages is created as a
result of the magnetic field, the induced voltages in such a
direction that its magnetic effect will oppose the Change
that produce it.) The output voltage vary according to gap
between probe and observed surface by these two laws.
| Is This Answer Correct ? | 22 Yes | 3 No |
Post New Answer View All Answers
What is feed factor and its Importance in cement industry? How we can solve feed factor?.
If we increase only P what will be controller action ?
what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com
why I need valve guard and whats different between guard and positioner ??
How to calibrate Magnetic flow Transmitter in Field
Is there any relation between Artificial Intelligence and Instrumentation?
What is the diffrence between digital signal processing and discrete signal processing?
you are on site,the plant trips,you are approached by operations,what do you do?
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
Positioner usage.
Boolean algebra
i hav applied for the post of engg. in iocl so please require the past test papers fro instrumentation engg please please help me and send me the papers or tell me the pattern and type of ques asked in examination......
Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose
Please can anybody help for control valve sizing step by step procedure?