Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are performing residue on ignition?

Answer Posted / tushar

because in residue on ignition we find out related
Substances (inorganic element like As , Pb etc) in muffle
furnace at 600-650 degree temperature in this condition all
residual solvent vapourized and only inorganic element
remains . refer USP METHOD-II

Is This Answer Correct ?    18 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2214


Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18

1911


Why sodium hydroxide used for maintain pH of phosphate buffer

2405


on the basis of bcs class how to proceed the solubility?

763


What is rs test why we are performing rs test?

1854


how can give the expiry period and restadardisation of volumetric solution

2582


Is it nessesary all multimedia dissolution require descriminatory?

791


what you do when compound having dwel wavelength?

740


what is different when impergnated silica plates are used in separation of azo dyes using column chromatography?

2022


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4056


how to set sample and standard concentration in RS method?

893


what is diffrence between specificity and selecivity?

764


how many types of balance calibration test?

2296


why are measure gas flow " ml " in Gas chromatography

1653


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2576