why are maintine power factor 0.99 in Eb line?
why are used capacitor bank in Eb line?
what is the purpose capacitor bank?
Answer Posted / perambalur sakthivel
(1)the cosine angle between voltage and current is called
power factor ,
already we know very well about cos value
cas 0= 1
(2)whenever the cosine angle between voltage and current
zero time a full power is utilized / consumed
but power factor lagging time a full power is not
utilized/consumed
(3)so we are maintained in power factor in unity
(4) to regulate voltage in power system we are used in
capacitor bank used(vanthni@yahoo.com)
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
what exactly commisioning work does in electrical site work... LT side?..
Explain difference between stand by earth fault and residual earth fault protection?
What is Auto Mains Failure Panel & Auto Synchronizing Panel
On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?
What should be the length of transmission line so that we can see/obtain the full sine wave of voltage??
What should be the protection scheme for a 15kw, 3-phase motor working in a lathe machine.
what is Anti-pumping?
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
Can anybody just suggest about the scope of Electrical design with ETAP software?Just guide me?
How can we calculate strength of copper hich is supplying electric power to heater and in it hold the heater also and what r all types of forces which is acting on it...
Starting current of a 10 HP induction Motor is ______ time’s full load current.
how a flip flop can be used as a latch?
On what principle electric motor works?
How to measure current and voltage in an ELV circuit
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?