Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the meaning of linearity,principle of co-relation
coefficient?

Answer Posted / ssr. krishna

Numerically how much ability of the method. It directly
proportional to conc of analyte criteria depending on
guidelines in general 0.99

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why we use glass fiber filters use in some situation?

800


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3178


if tech transfer fails whay require to do?

847


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2788


Why we use potassium dichromate in uv calibration Exact reason behind it??

1259


why cone formation during dissolution?

787


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2729


Why we check moisture,ash & AIA in product

1885


in dissolution why pool sample needed? in which type of drug pool sample need?

3180


if you have given a blank water how you analyse by general analytical techniques?

2032


What should be the level/ Percentage of Arsenic in Arsenic free zinc.

2233


WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2609


Why a1% value is used for some product ? What is the criteria for selection a1% value ?

2346


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4074


if content uniformity passing but dissolution varrying then what is next step?

879