Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the advantages and disadvantages of oil filled cables
over XLPE cables

Answer Posted / anil

now most of the HT and EHV cables are with XLPE insulation.
earlier, in mid 70's HT cable are insulated with PILC(paper
insulated and lead covered. OIL is filled to reduce moisture
in paper. disd of PILC cables is very heavy almost double
the weight of XLPE cable but adv is the chance of voids are
very less in PILC cable. Lead is not ECO-friendly,it is
almost banned in europe, US and few countries in ASIA. Cost
is very High as compare to XLPE cable. whereas XLPE cable
are lighter in weight.Long life,easy to handle. jointing is
less costly.

Is This Answer Correct ?    5 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2098


What is the basis for framing the rules of block diagram reduction technique?

1463


testing of Vector Group – YNaoD II

2870


What is excitation in case of dc motor?

1113


in non technical way how can u define POWER FACTOR??

1768


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

1996


If you have an earth with pilecap then your resistance is really low. why and how?

1940


what is the advantages og idmt relay over magnetic relay??

4187


how i chosse capacitor bank if my energy meter is 48 kvr? tell me capacitor bank chossen formula?

2277


What are two contours of nichols chart?

1017


how to introduce yourself

1983


Why 1/3 is used in symmetrical components?

1781


Sir, I m 3rd year student 4m DCE and want to do internship in siemens or l&t or any other mnc related to electrical engineering. please tell me the procedure 4 same and oblige me

1939


A motor running with lenze frequiency inverter stops if I REDUCE SPEED with 25% load.If I run it in High speed and medium speed running smoothly with full load.please help me to solve it.

1937


What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.

2543