Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

at present how many 765 kv lines are there in india?

Answer Posted / k.prakashchandra

According to the newspapers, one 765 KV line of 351 Km
length has been commissioned between MP and Chattisgarh

Is This Answer Correct ?    15 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can anyone explain the star-delta motor control wiring ,which wire go where and how they operate?

1497


for 5KW resistive load can anyone please suggest me whether to go for UPS/Inverter or Generator depending upon cost calulations

2149


where lt & ht capacitor used

2279


33kv substation lay out details & line to line & line to earth measurements

2673


what is thermal resistance of PVC Cable.

1858


how to produsing geretor power

2252


why zero sequence impedance measurement is not applicable for single phase GT

2249


What is the difference between AC and DC injection methods for rotor earth fault protection

2266


what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?

2314


how point on wave controller works.

2649


why i can not use thimble on capacitor duty contactor

1396


L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.

1146


why capacitive load is not used in routine life????any reason is there ??????

1865


My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible

2153


How does a battary stores charge in it? please explain in simple manner and in detail.thanks

2037