Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

hay friends, i am in trouble to understand PID controller.
several times i have study but it is not clear to me have
you a simple way to understand.

Answer Posted / yashwant

SEE THE SIMPLEST WAY WILL BE DEPEND ON YOUR REQUIREMENT OF
PROCESS, WHETHER YOU WANT SLOW OR FAST RESPONSE AND ACCURACY
YOU WISH. P VALUE FASTEN AND SLOW DOWN PROCESS, IF YOU REDUCE
VALUE OF P LESS THAN 1 PROCESS WILL BE ACTING VERY SLOW AND
ACCURACY ALSO WILL BE GOOD, AND IF IT IS MORE THAN 1 SYSTEM
ACTS SOME WHAT FAST AND FORWARD O/P IS EXPECTED.
I VALUE DECIDE THE SPAN AND SPEED WHILE REACHING SP AND AWAY
FROM SP. D IS USED FOR VERY FAST RESPONSE IE ON OR OFF VERY
FAST ACTION IT IS USED VERY RARELY AS PER PROCESS REQUIREMENT

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com

2329


what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d

5400


Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com

907


what is basic difference between motion balance and force balance in pneumatic instrument?

9669


where uses EXe /EXd/Exo/Exn/Exp/Exq/EXia

9925


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

2456


we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.

2065


we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.

2611


How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.

2141


Why plc require in analog input 4-20amp & 0-10 volt?

1140


why we take %i0.0 as input for twido plc

2175


what is actual drum level and compensated drum level?

2230


what is the calibration procedure for magnetic flow meter @ onsite

1655


What are the application of bernoulli’s theorem?

1150


what is droop in governer ,type of droop ,how it work

2155