What is d role of reactive power in power system??How it
produce & consume?
Answer Posted / priya
it is used to improve power system operation by controlling
power factor.
It is produced in inductive(lagging) and
capacitive(leading)elements. Reactive Power represents the
power used in changing electric fields or magnetic fields of
circuit components, but is power that is UNAVAILABLE to
perform real work. Apparent Power is the power that the
generating circuit "thinks" it is supplying, but it equals
both reactive power and real power and only real power can
accomplish useful work like turning a motor.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is ideal IR values for ground and neutral.
when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
please send me latest & previous years question papers for IOCL Technical level questions
How many types of colling system it trformers?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
i want to apper for apgenco or aptransco or related can any one sugest me where can i get previous papers of thouse exams
hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com
how test transfomer(3 phase75kva) by megger
what is ratio of copper wire size and current ?
why the rotor current becomes in steady state during high slip region? please verify with equations.
what is the meaning of 5% droop or 7% droop in AVR?
what is the correct format to create a resume for interview??
HOW TO CALCULATE THE HEAT AND LOAD OF LT-SUBSTATION WHICH CONTAINS 2*1MVA TRANSFORMERS,LT-SWITCH BOARD,MLDB,ACB,BUSBAR,ETC,......?
Which of the following alternatives will be cheaper (1) A 100 h.p AC, 3-phase motor (2) Four motors of 25 h.p each (3) Five motors of 20 h.p each (4) 10 motors of 10 h.p each explain