Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can we perform parallel operation of two transformers when
one transformer on load?

Answer Posted / vysakh v

when two transformers has to be operated in parallel,their voltage ratios must be the same,Polarities of the transformers must be the same,Percent (per-unit) impedances of the transformers must be the same,Phase sequences and zero relative phase displacement of the transformers must be the same.

Is This Answer Correct ?    7 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

placing earthing pit in pathway is correct or wrong??. placing earthing wireGI1/18 inside walls is correct or wrong?. explain!!!

2099


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1930


can anybody sent me power grid questions. what subject should i prefer for preparation?

2063


can any tell me why slope 40% and 80% is calculated in differential protection?

1838


What is the need for a controller?

1143


where can i get vijaya electricals limited in hyderabad interview auestions can u give me the website address plz

2077


How to use computer cpu ups use for home inverter circuit board

1725


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1694


primery try cell?

2128


What is the Minimum winding resistance of motors ( small & big)? referance range

2255


It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.

3801


why normally Generator rating are between 11Kv to 22Kv?

4526


gas turbine genrator reactances

1945


WHAT ARE THE DISADTAGES OF SINGLE-WIRE-EARTH-RETURN SYSTEM USED FOR RURAL ELECTRIFICATION?

1931


Is there any type of starter for DC motor other than two point,Three point and Four point starters?

1976