Based on CPI/CGPA they shortlist the candidates & than
directly start Interview so there is no Written Exam or GD
Only PI.Interview held @ MNNIT , ALLAHABAD On-Campus on
6th,Aug, 2007 & the Questions asked to me by Interview Board
( 4 People) are from HR/SummerTraining/BTP/Subject-core,
POWER SYSTEM & MACHINE. time duration of I/V is about 15-20
Minutes.

HR-

Q.1 Name,hobbies & About family background ?

Q2.What u know abt NTPC ??

Q3.Why u want to choose NTPC as ur Carrier's starting i.e
power sector not any other Oragnisation or sector ??

Techincal Questions-

Q1.What is the reason for transformer Noise ??

Q2.Which material is used for making Transformer oil & How u
measure its dielectric strength & Name the test ?

Q.3 Which Machine u will prefer 2 use if flammble gases are
coming out at a place & why ??

Q4.What is relation b/w Transmission Lines & Communication
Lines ?

Q5.What is the maximum capacity Synchronus Machine & total
powerGeneration in our country ?

Q.6 In india Power generation is at 50Hz while in America
its 60 hz ,why so ?? Advantage or disadvantage ??

Q.7 Maximum Generation Voltage in india ?

Q8. What is the Voltage regulation & why its required n how
much is permissible ? & causes of voltage variation ??

Q.9 Why electric shock is feel ?? n in a Electric Train why
we didnt feel that ?

Q.10 Have u seen/ experience of any power plant/ industry
related to the power sector ?

so these are the questions which not too diffcult i
think was asked to me.

Answer Posted / yuvaraj kamle

Answer for Q1

when we will give the supply at primary side the transformer core will COMPRESS and ELONGATION and this
is called MAGNETO DESTRUCTION,DUE to this reason the transformer make noise.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

while starting a liquid starter ,is there any volage drop on water/soda on tank.can we touch the tank on starting?

1449


Why wind turbines wheels rotate constantly

647


Define corner frequency?

768


how to select battery for 15 KVA UPS with formula

2097


send me all basic electrical question and answers

2539






What is the tension required for the 25000 CFM AHU belt

2056


how i calculate the syncrones generator NGR resistance .if we have a 6mw generator line voltage of generator 11kv also line current 393.3 ampere.

1667


why high speed tripping relay will be used in tripping circuit why not normal relay

833


what is differentila pilot supervision in the incomer control panel in the power station?

1632


How to decide CT & PT ratings for a given transmission line carrying some rated voltage?

1890


What is the angle of inclination for the oil connection from transformer conservator to Bucholz relay and why?

1703


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

1683


What are root loci?

657


Explain using drawings what is reverse PID action w.r.t PID controllers.

2761


Why does the rotor rotate?

1817