Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE DIFFERENCE BETWEEN PLC AND DCS

Answer Posted / anitha

plc is a progrramable logic controllers & dcs is a
distributed control systems.In brief PLC is product
controller.DCS is process controller.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

the 3 most common transmitter protocol being in refinery or qatar gas and aramco.

2948


Turbidity analyzer working principle ?

1782


Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?

1990


Define cryogenic?

1169


I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?

2208


in differential pressure transmitter,min&max pressure range for hp&lp

2003


send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com

2222


what is interface level measurement.who can calibrate interface level measurement transmitter online

2524


how to work MIL contol valve posistioner ?

2145


we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?

2586


Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

2080


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1944


where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve

1772


How to calibrate an pressure gauge with yantrika test bench?

2909


what is actual drum level and compensated drum level?

2230