I am an electrical contractor in noida, I am registereg in
noida vat. i got a contract in Delhi State, my party told
me that we shall deduct WCT @4% & reimburse Service tax all
in composite scheme.
Now Problem is this,
1 Can i able to purchase outside the delhi?
2 Can i produce a c form to our vendors?
3 What is limitation of purchase from outside the Delhi?
4 What % of tax Govt will levied upon me?
5 How can i take credit of tax paid upon purchase made by
us.
So, like these type questions i have in my mind if any
person know the right answer please write to
sksproj@gmail.com or contact me on - 8010076534 /
9212758177 / 9718378190.
Thanks with Best Regards,
S.K.Saxena
Answer Posted / lol
call architect
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
why Lightening Arrester Probe sharp at Top of telecom tower.
1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)
How to Calculate The sag of OPGW in Transmission Line???
how can we change the polarity of Alternating current rapidly? how frequency of ac can be controlled and changed easily?
how tto ingress mw in turbine explain.procedure ?
why and how current drawn by battery charger depends upon the altitude where it is located?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
The electromagnetic torque developed is proportional to what in a D.C series motor?
Explain what is use of lockout relay in ht voltage?
how to changeover ups in this power failur time?
is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
Draw the circuit of clapp oscillator?
According to conduit size which size wiring & how many wires can we provide wires in conduit & how can we select conduit size accordingly?
What is an automatic controller?