Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

for preparation of design note of 11 / 220 kV , 3 phase,
63 MVA transformer how can calculate or consider the iron
losses and copper losses

Answer Posted / aamod tripathi

The Iron and copper losses are determined by tests only. It
is guaranteed parameter. If not met . the manufacturer has
to be imposed with a penalty calculated according to the
life of the transformer.

However as a thumb rule. 63 MVA transformer will have 1 -
2.5 % of no load + copper losses.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define peak overshoot.

1277


if 3400kw slipring motor rotor shorting done and motor started on mv drive ,what will be the rotor shoring current

1722


I want to know how to calculate the size of electricity cable in building?

2021


HOW THE OLTC TRANSFORMER SAVE ENERGY IN COMPARISON TO OFF LINE TRANSFORMER AND IS IT ECONOMICAL TO REPLACE THE OFF LINE TRANSFORMER TO OLTC TRANSFORMER

2200


briefly explain principle of resistance welding

1854


If we are given a 10 amp cable type and asked to calculate the number of cores used and the thickness of the cable, how do we do it?? please help...urgent!! i hope the question is clear enough!!

1832


On what basis the the size of Lightning arrester for buildings are selected ?

1660


what is the meaning of osr in transformer.

2150


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2035


boiler is running in rankine cycle and deisel generator is....?

2054


How to improve fuel cell in a distribution system?

1995


What is called limb of a transformer?

1050


what is the working principle of a DG Set, Alternator, & exiter

10224


Draw a block diagramof Three UPS systems connected in Parallel mode?

2169


What are the different sign conventions used in electric circuits?

1170