Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

There is two transformers of 2MVA & 3MVA, which transformer
is located at the sending end & which is at receiving end.
why?

Answer Posted / elaiyaraja

always the sending end transformer must have higher value
then receiving end . bcoz if load suddenly increased it can
able withstand the sudden demand...

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT CAUSED THRESHOLD VOLTAGE TO EXIST?

4073


In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?

1980


what is effect of leading power facter on the system and billing

2343


hi , i have 150 kw loud and we need 50 m cabil,i want to know wich size cabil we use. thanks

2164


what & how to check the lightning arrester

1919


The electrical energy required to raise the tempreture of a given amount water is 200 kwh. If the heat losses are 20%, the energy required is?

2012


what is interfacing in computer studies?

1785


As we use capacitor bank in 3ph ckt to improve PF, can we use capacitor in single ph domestric use, in house we have Fan,Mixer,electric cooker,iron,tube choke they also lag the system,because it is inductive load. if it is possible to improve PF of single ph system-- if yes- type of capacitor to be used,connection diagram, working in detail. if no-- list it.

1780


What is the basis for selecting Vk/2 or Vk/4 for REF and Differential protection of Transformer and What is the significance of magnetising current

2403


we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

1679


how to calculate the earth mat design in 132 kv substation yard ????

6248


why tertiary winding is used in transformer with diagram?

2253


any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?

2146


can i connect REF and Differencial relay in 1 CT core for transformer protection?

1960


I WANT HOW CALCULATE TO CABLE FOR WELDING PLANT ?

1836