Answer Posted / raj
IT IS NEUTRAL DISPLACEMENT RELAY AND IT IS USED FOR VARIOUS
PROTECTION BUT THE PRINCIPLE IS THAT IN CASE OF NO FAULT NO
VOLTAGE IN RELAY ( IT USED OPEN DELTA VOLTAGE FOR RELAY
INPUT ) AND IF FAULT OCCUR IN ANY PHASE THEN UNBALANCED
VOLTAGE WILL GET ACROSS OPEN DELTA FOR RELAY TO OPERATE.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Fantio of tranformer
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
WHAT IS THE WORKING PRINCIPLE OF A GENERATER.how is a GTG (Gas TURBANE Generater) working.plz explane
A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.
(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?
technically, what is the reason behind starting the motor star the delta connection .. and what other ways to do this rather than using " star-delta transformer"
What are unstable systems?
Dears we deal in Chemical are Plate earthing. Kindly call if any requirement and questions. Tech Earth Solutions Mohit Verma 8791071007
Whether the vacuum contactor requires Short circuit protection?If No,why?
In synchronous motor, how the field current is related to armature current..i know its inversely proportional..but concept wise...i was nt clear....pls help me...
we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.
If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer
i need project topics along with circuit diagram in the electrical and electronics engg and also some websites regarding projets.
list the advantages of RCCB over other circuit breakers?
how to calculate the formula of cable size if motor kw is given