Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

explain how hunting can be reduced in an alternators?

Answer Posted / n.v.patil.

By putting damper winding in Yoke of field circuit

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..

1936


wat is d diffr btw shunt coil and trip coil in VCB?

2826


How many methods use the load flow solution?

1335


what is difference between 2 pole structure and 4 pole structure in transformer yard

6045


I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2266


what is tri state logic gate

2192


what is the function of gss in the dg set.

1951


1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?

2903


why cable i burning without tripping. how can protect led street lights

1556


how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you

1996


what is the reactive power what is the use of it in system

2154


what is the principle of the single phase energy meter? and,what is the advantages and disadvantages of single phase energy meter?

4538


What is meant by stator? What is meant by rotor?

1115


can any one know is sbi interview based on merit or based on roll number

1980


What is meant by coupling capacitor?

1059