Difference between induction motor and synchronous motor?
i Think Synchronous motors operate at synchronous speed
(RPM=120f/p) while induction motors operate at less than
synchronous speed (RPM=120f/p – slip). Slip is nearly zero
at zero load torque and increases as load torque increases
am a right pls guide & send Other Comments
Answer Posted / arpit
synchronous motor is not self starting while induction motor is self starting...
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
electrical knowelge
What happen Grid EARTH plat got cut.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Match the following a)(X'+Y') b)X'Y' C)XY 1)NAND 2)NOR 3)Carry
How to calculate VCB rating for 33KV ,25 MW Power line?
Is a d.c.compound motor is use as a booster? how?
What are the electrical engineer roles and responsibilities in chemical plant?
What is mathematical model of a control system?
do we use links in a dc circuit?if so what s its use in it?
what is the difference between ac motor and dc generator
please give me solution to rectify the emi(electromagnetic interference)
Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
Why should we hire you over the others waiting to be interview?
how generator load test is conducted?what are the steps?