What is the relation between electronics & instrumentation
Answer Posted / tapu_93
Instrumentation uses electronics for its measurement,
control and protection.
Electronics is independent engineering for applying in
various engineering application.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
What is difference between ESD and PLC please Explain me clearly.
what is the difference between active & reactive power?
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
Explain the use of hair spring in the pressure gauge.
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
What is voltage regulator?
what is the usage of QDV & VOLUME BOOSTER
Why do we floating DC in DC system.
Why boiler chimney area oxyden sensor fixing?
What is wet leg condition and why is it used?
how to work MIL contol valve posistioner ?
Can I calibrate the Electromagnetic Flow Meter on line and How.
you must show the examples application and give at least 4 types of transducer/sensors that can minimize the failure during the manufacturing of the resistors.
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?