Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between KV,KVAR,KVA,KW?

Answer Posted / tarun aggarwal ymca

First take out odd kV= its the Potential difernce (Volt) in Kilo volts
KVA (Apparent power)=vector sum ( kW{active power}+kVAR{Reactive power))

now to tell u in breif in analogous way abot this KVA ,KVAR,KW

suppose we have to take one ball from A to B then

if the path is flat Road the power used is called active power

now if the path is upside of incline road the to take the ball we do extra effort
1) active power work to take ball from A to B
2) reactive power work to take in incline up side (extra work )

but total power used in this case will be greater and work done is same taking ball from A to B, this power is called as apparent power
active and reactive power

Is This Answer Correct ?    24 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2271


How to detect voltage vector shifting in interconnection protection.

1964


If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer

2769


What is the difference between earth fault protection of motor feeder with CBCT and Without CBCT ?

3000


In hydel power plants, L.A's, S.C's are placed inside the control panel boards. what is the purpose? [already the total body was earthed to ground.]

2026


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1646


I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.

1516


Can we use a absolute encoder to show rpm of a motor ? what about the condition when power is off ? what is difference if a incremental one is used ?abanirout@gmail.com

2079


we have 3 single phase transformers. how will we generate 6 supply from 3 phase supply input

2159


What is accuracy of a measurement?

1188


what is rating boiler

2049


What do you understand by external characteristics of a d.c. Generator?

1159


Why does amplifier gain reduce?

1101


What is the settings of distance protection relay in 400 kv line

1753


how to differentiate a mpcb,mcb with a contactor? Explain their working operation

2286