Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why America use 60HZ 110V?

Answer Posted / gnanprasad.korrapati

When the German company AEG built the first European generating facility, its engineers decided to fix the frequency at 50 Hz, because the number 60 didn’t fit the metric standard unit sequence (1,2,5). At that time, AEG had a virtual monopoly and their standard spread to the rest of the continent. In Britain, differing frequencies proliferated, and only after World War II the 50-cycle standard was established. A big mistake, however.
Not only is 50 Hz 20% less effective in generation, it is 10-15% less efficient in transmission, it requires up to 30% larger windings and magnetic core materials in transformer construction. Electric motors are much less efficient at the lower frequency, and must also be made more robust to handle the electrical losses and the extra heat generated.
Today, only a handful of countries (Peru, Ecuador, Guyana, the Philippines and South Korea) follow Tesla’s advice and use the 60 Hz frequency together with a voltage of 220-240 V.
Originally Europe was 110 V too, just like Japan and the US today. It has been deemed necessary to increase voltage to get more power with less losses and voltage drop from the same copper wire diameter. At the time the US also wanted to change but because of the cost involved to replace all electric appliances, they decided not to. At the time (50s-60s) the average US household already had a fridge, a washing-machine, etc., but not in Europe.
The end result is that now, the US seems not to have evolved from the 50s and 60s, and still copes with problems as light bulbs that burn out rather quickly when they are close to the transformer (too high a voltage), or just the other way round: not enough voltage at the end of the line (105 to 127 volt spread !)

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is a DC series motor?

1234


how to know the diffrential relay setting of 06mva step- down (delta-star)transformer?

2022


Why is a synchronous motor always star connected??

2599


what is sevice settings for mccb?How can be it setted?

2217


Can anyone please provide me details of MCCB/Contactor/SFU rating calculations for a motor feeder..for example 50 kw.. not from type-2 cordination chart. i want manual calculations..

2581


In general bus riser follows the bus section in SWGR. What are impacts if bus section follows bus riser?

1542


what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.

18440


How to calculat the ratio of HT\LT in energy meter

2697


How to Calculate KA Rating of Main LT Panel

1744


is there any lightning by passer is arranged in ship like buildings?

1932


anyone knows service engineer in chennai for EDM SPARKING MACHINE.CHMER PULSE CD 60 M.pL GIVE ANY CONTACT NOS

2408


What is difference is of VSD,VFD,VSDS, are they the same as the direct current to control dc using above mention

1507


ACCORDING TO IEC WHAT SHOULD BE THE MINIMUM HEIGHT OF G.I. STRUCTURE OF CT, PT, ISOLATOR, LA?

2190


What is the use for cable entry in control room?

1165


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

2595