why America use 60HZ 110V?

Answer Posted / gnanprasad.korrapati

When the German company AEG built the first European generating facility, its engineers decided to fix the frequency at 50 Hz, because the number 60 didn’t fit the metric standard unit sequence (1,2,5). At that time, AEG had a virtual monopoly and their standard spread to the rest of the continent. In Britain, differing frequencies proliferated, and only after World War II the 50-cycle standard was established. A big mistake, however.
Not only is 50 Hz 20% less effective in generation, it is 10-15% less efficient in transmission, it requires up to 30% larger windings and magnetic core materials in transformer construction. Electric motors are much less efficient at the lower frequency, and must also be made more robust to handle the electrical losses and the extra heat generated.
Today, only a handful of countries (Peru, Ecuador, Guyana, the Philippines and South Korea) follow Tesla’s advice and use the 60 Hz frequency together with a voltage of 220-240 V.
Originally Europe was 110 V too, just like Japan and the US today. It has been deemed necessary to increase voltage to get more power with less losses and voltage drop from the same copper wire diameter. At the time the US also wanted to change but because of the cost involved to replace all electric appliances, they decided not to. At the time (50s-60s) the average US household already had a fridge, a washing-machine, etc., but not in Europe.
The end result is that now, the US seems not to have evolved from the 50s and 60s, and still copes with problems as light bulbs that burn out rather quickly when they are close to the transformer (too high a voltage), or just the other way round: not enough voltage at the end of the line (105 to 127 volt spread !)

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?

967


what is th basic difference between a d latch time line and a d flip flop time line???

1473


how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?

2515


how to calculate the settings for shaft ct protn in hydro generators

1506


Is electro plating what type of load whether resistive, inductive or capacitive loads

2907






what is the principle of the single phase energy meter? and,what is the advantages and disadvantages of single phase energy meter?

3962


1.main parts of generator? what is used A-check,B-check,C- check? 2.what is FM200 system in data centers? 3.difference between pac,ahu?

1673


Discuss the effect of sudden loading of an induction motor

1395


how can maintain the power factor and why and this is how do work tell us

1557


please send me last 5 year interview questions

1673


how we will deside the high voltage value

1464


What is the estimated total hydropower potential of india?

633


State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor

2010


what is earth pit , how we can measured it, what earth rods reference

2071


sir am giving jspl exam on 19th oct . i belong to eee, so plz send previous question papers ..........to dis id abhilash203@gmail.com

1997