why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11

Answer Posted / divyanshu yadav

its really jst a misconception that generated voltage has to do anythng with form factor...
this is just a hypothesis made by our old generations......
as raman said above that nowadays we are using 230v and even 765kv which is not a multiple of 11...

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT ARE THE CHARACTERISTICS OF AN VOLTAG AMPLIFIER

1605


Define what is difference between fuse and breaker?

675


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

1574


sir my exam is on 19/6/2013 under electrical branch pls send me sample aptitude questions as well as sample technical questions for jindal steel and power company

1754


what are the factors to be considered while design the breaker either HT or LT??

1411






How line capacitance & line inductance varies with increase in height tower.

1869


Why lose 1 phase voltage in 33kv to 415v stepdown transformer

1319


what is Fan Control Cubicle

1892


What is open delta Xformer? It's adavntages & Use?

1784


What are safety device in vcb and acb?

3272


Hi,I am working in abroad for more than 3 years in a company operating with 11kv and 6.4 MW power. I need c licence in India,can I? some other says only i can get if i work for 2 years in india only! anybody kindly clarify by doubt.Thanks

1478


Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.

1295


how many stairs have you climbed while you were coming

1702


how many safety really of DG sets.

1729


why a tester wont shock while testing the power in house

1331