Why in a three pin plug the earth pin is thicker and longer
than the other pins?
Answer Posted / rajesh
If leakage current or negative sequence current happens in a
particular system,they cause severe damage in that
system.for prevent that system we provide less resistance
path(r=pl/a).if resistance is inversely propotional to
area.we use large size cable.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
Define sensitivity?
What happened if C.T mount at any cable or Bus bar in wrong direction . C.T going on proper work or not . C,T direction is essential thing to properly work.
Write the analogous electrical elements in force voltage analogy for the elements of mechanical translational system.
why cable i burning without tripping. how can protect led street lights
What is the HVDC Transmission System? What are the conditions applicable to lay an HVDC Line?
Inverter. converter. Ups.MCB.solar.alternators. motors.
what transformer we used normally and upto which kva?
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
how to calculate slip ring induction motor stator and rotor currents??
What are the effects of electrical faults?
Whar is the KvA rating of 33Kv substation & actual kv rating of power generaating station.
Explain the functioning of diode?
in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly
what is earth resistance? how to measured? and give values at power station and mcc area?
The power supplied to a 50mH inductor from a 120V, 60Hz source will be